bodeplot's Issues

aborting the measurement fails

Sometimes aborting the measurement fails.
So far this has only been observed when aborting from the GUI.
In some cases, this also leat to MATLAB crashing.

Name Propositions

  • Frequency Response Aquisition via Matlab - FRAM(-App)
  • Remote Aquistion of Magnitude and Phase via Matlab - RAMPlab

Investigate caching

caching instrument properties could improve performance and minimize queries.
How about that?

Auto scaling issues after removing output disable

Previously the output was disabled before changing printing the new frequency.
This was done primarily because it seemed like the new frequency setting was read by the instrument successfully, but had no effect on the output.

I have now removed this toggling of the output to reduce wear on the relays.
So far the frequency setting seems to affect the signal output correctly, but a new problem has emerged:
image
The built-in autoscaling of the scope is now struggling to display the signal correctly which results in invalid voltage and phase readings. But only for the first one to four readings. This was taken with eas on.
This problem only occurs sporadicly.

Accuracy of the measurement

The accuracy of a measurement depends on the combined accuracy of the instruments used as well as on the quality of the setup.
I have found that with my instruments, namely a fully upgraded DS1054Z with 100 MHz bandwidth and 24 Mpts (so technically a DS1104Z) as well as a stock DG1022Z I can achieve the following results up to 10 MHz:

Magnitude/Attenuation, maximum error: better than (pm) 0.3 dB
Phase, maximum error: better than (pm) 0.1 rad

Setup:
1 m RG58 coax from output 1 into a t-splitter mounted directly to ch1 of the oscilloscope and whose other end connects to a 30 cm RG58 coax and into ch2. The cables are from good quality manufacturers but I fished them out of my universities dumpster so there is a good chance that something is wrong with them.

spec
As you can see on the plot above, for frequencies above 10 MHz the magnitude rises up to 1 dB for 25 MHz.
I have jet to figure out what exactly causes this behaviour.

Recommend Projects

  • React photo React

    A declarative, efficient, and flexible JavaScript library for building user interfaces.

  • Vue.js photo Vue.js

    🖖 Vue.js is a progressive, incrementally-adoptable JavaScript framework for building UI on the web.

  • Typescript photo Typescript

    TypeScript is a superset of JavaScript that compiles to clean JavaScript output.

  • TensorFlow photo TensorFlow

    An Open Source Machine Learning Framework for Everyone

  • Django photo Django

    The Web framework for perfectionists with deadlines.

  • D3 photo D3

    Bring data to life with SVG, Canvas and HTML. 📊📈🎉

Recommend Topics

  • javascript

    JavaScript (JS) is a lightweight interpreted programming language with first-class functions.

  • web

    Some thing interesting about web. New door for the world.

  • server

    A server is a program made to process requests and deliver data to clients.

  • Machine learning

    Machine learning is a way of modeling and interpreting data that allows a piece of software to respond intelligently.

  • Game

    Some thing interesting about game, make everyone happy.

Recommend Org

  • Facebook photo Facebook

    We are working to build community through open source technology. NB: members must have two-factor auth.

  • Microsoft photo Microsoft

    Open source projects and samples from Microsoft.

  • Google photo Google

    Google ❤️ Open Source for everyone.

  • D3 photo D3

    Data-Driven Documents codes.