omenukas avatar omenukas commented on June 26, 2024 1

Everything is fine with the outdoor temperature sensor - I'm using an external Panasonic temperature sensor, which is on the north side of the house and the sun doesn't shine on it.
My questions about the other one:

  1. if the RTC is set to 20C in the living room, and the real room temperature is 22C, why does the heat pump still heat? According to the temperature curve of the pump, it is 33C and although the RTC correction shows -3C, the temperature shift in the pump is still set to 0C and 33C is supplied to the radiators. Shouldn't it be 30C? Am I not understanding something?
  2. Another question - Is it possible for the pump to work not according to the curve but according to the room temperature and the room temperature sensor is my individual temperature sensor and not the Panasonic panel or the Panasonic external room thermostat?
    p.s. I can't show you my graphs now because it was warm outside these days and I had the heating turned off at the pump.

from nodered_heishamon_control.

omenukas avatar omenukas commented on June 26, 2024 1

Oh, when WAR is disabled, then "water temp." becomes active again? Maybe it's logical

from nodered_heishamon_control.

edterbak avatar edterbak commented on June 26, 2024 1

Sounds like a plan. I will take this onboard. Thanks

from nodered_heishamon_control.

omenukas avatar omenukas commented on June 26, 2024 1

The beta version is not with me, but with a colleague. He confirmed that yes - both parameters are "0".

from nodered_heishamon_control.

geduxas avatar geduxas commented on June 26, 2024 1

@omenukas sorry for taking this topic, also i am new to node-red, but your script should work fine, your script just get's all temp, and passes only lowest value.. so input should receive single lowest value. One thing that i am missing i'ts payload topic. Don't know if flow is looking for topic, but i use almost same for myself.. and after that just compile one payload with my custom topic name, and everything works fine.

from nodered_heishamon_control.

omenukas avatar omenukas commented on June 26, 2024 1

@geduxas
Oooh, yes. You were right. How did I not realize this myself. Everything is fine now.

from nodered_heishamon_control.

edterbak avatar edterbak commented on June 26, 2024

I think your heatpump is in direct sunlight at certain moments. Can you confirm this?

Be cause; based on what you describe I think what is happening:
The pump catches sunlight. The sensor gets warmer than actual outside-temperature, example 22C. Which is high enough to turn off.
When the sun goes away again, the sensor detects the actual temperature again ~10C

This is also what happens with my heatpump. It is on the roof and it catches sunlight. I have an external sensor (source = OpenWeatherMap) and use that as sensor for the outside temperature.

Today is see this:
image

You see there are a lot of moments where the gap between temperature REAL (2) vs SEEN (1) is 10-15C.

This is why I created my custom WAR function, which basically copies the function of the compensation curve, but is able to use any custom sensor instead of the built-in version.

You can also solve this by buying an external panasonic sensor and connect it to the pump. It has connections for that.

from nodered_heishamon_control.

omenukas avatar omenukas commented on June 26, 2024

I turned on the heating today and specifically lowered the room temperature setting. Is everything okay here? It seems to me that a lower temperature should be applied to the radiators.
image
image
image

from nodered_heishamon_control.

edterbak avatar edterbak commented on June 26, 2024

Ah. So direct sunlight is not it.

Are you using the pump in compensation curve mode?
I think so judging from the screenshot.

And can you check in heishamon if the dashboard sp corresponds with it? It might be a incorrect visual value, while the actual value used by the pump is correct. This could be the case. I hear more about this recently. Need to fix that.

Also you can check what is in the log of the dashboard. What does it show.

1: you are correct. The corrected sp should be 30, or if you are using the c- curve mode, -3. And not 0.

2: i think i understand you.
Yes. It should.
If you disable the Panasonic compensation curve mode. (set to direct)
This is why i created the rtc function. You can use any custom sensor as long as you have the measurement entering node red.

Are you using version 23.09?
If so. I am about to release v23.10 which brings a better and easier access to connect external sensor.

A short note:
I am concluding the flow does not yet work wel with the pump in compensation curve.
After v23.10, i will start working on it to make it stable for c-curve.

from nodered_heishamon_control.

omenukas avatar omenukas commented on June 26, 2024

Yes, the pump works according to the curve. I am using version 23.09.
I don't really understand what parameters I should compare, but I can confirm that WAR=33C has not changed since last week and it doesn't matter what the temperature is outside. Also, "shift curve=0C" does not change either on the dashboard or on the pump panel.
Although the room is warmer than set, the pump still heats.
image
image
image

from nodered_heishamon_control.

edterbak avatar edterbak commented on June 26, 2024

Okay,

This proves the flow is not working yet corretly in compensation curve mode.
Can you set it up to Direct mode, do a restart of the flow.

I am going to try to fix the issue this week. It will require me to do some serious debugging.
The more because I do not have a external thermostat, which is also another variation to the mix.

But, best is to have it working stable, with direct mode (heat+cool). Hopefully it will be a week at most, where after you can maybe help me to test this if it is working propperly after the work.

from nodered_heishamon_control.

edterbak avatar edterbak commented on June 26, 2024

But information for you on a slightly different topic.

The compensation-curve is the Panasonic version of the WAR-function in the NodeRed-flow.
Only limitation the panasonic CC has, is that is is hardwired to use the panasonic outside temperature measurement. inbuilt-or separate thermocouple.

But, long story short. If you have the Panasonic CC-mode enabled, the flow will detect it and automatically disable the WAR function.

Before you change to direct mode (if you are..) please press the IMPORT button on the WAR-function tab. It could be help to correct the read-out in the dashboard.

But do note that you will never get the WAR function from Node Red working/enabled. It will auto-disable in a short while.

from nodered_heishamon_control.

omenukas avatar omenukas commented on June 26, 2024

Of course I will be able to test the patched version.
Regarding the Direct mode....I have never used this mode and I have no idea what value the water temperature should be set to

from nodered_heishamon_control.

edterbak avatar edterbak commented on June 26, 2024

Of course I will be able to test the patched version. Regarding the Direct mode....I have never used this mode and I have no idea what value the water temperature should be set to

😃
You currently have the panasonic CC function running right?
Are you happy with those temperature settings? Do you experience discomfort? to hot/cold at times?
If you are happy with it, you can just use this setting.

Befor you change to direct mode, make a screenshot of the settings with your phone. The settings in the controller of the curve.
Then in the node red flow, do the IMPORT in the WAR menu tab.
Then change the pump to direct mode
The settings should not have changed in the node red dashboard.

This should do it and you are using the Node Red WAR function if you enable it.

If your not happy with the node red implementation or run into issues. You can always go back in the controller, set it back to CC and enter the temperature again as you had them. THats why making a photo of the controller us usefull..

from nodered_heishamon_control.

omenukas avatar omenukas commented on June 26, 2024

Ok, I switched to Direct mode. What does this "Water temp." parameter?
image
image

from nodered_heishamon_control.

edterbak avatar edterbak commented on June 26, 2024

Water temperature, you can set. If you do not use any of the functions, this will be the setpoint.
Once you enable WAR, it will overwrite the given [water temp] with the calculated one.
If you enable RTC, it will correct the setpoint from WAR/Water temp.
etc.

Read it from top down. 😄

from nodered_heishamon_control.

omenukas avatar omenukas commented on June 26, 2024

I thought so. Just showing the same 33 degrees as in curve mode :)
Ok, I'll wait for the new version for testing, because I briefly ran the Beta version last week, I didn't understand anything about the sensors and went back to the stable version :)

from nodered_heishamon_control.

edterbak avatar edterbak commented on June 26, 2024

Sounds like a good action. Ghehe... It is indeed still in beta. First i want to have the logic/design and function in order, then I will start working on the help text etc.

The design/function seems to be going well now, but still not good enough for new users.

from nodered_heishamon_control.

edterbak avatar edterbak commented on June 26, 2024

I thought so. Just showing the same 33 degrees as in curve mode :)
On that note: I can maybe think of making the 'Water temp' option grey out if the WAR function is enabled.
What do you think?

from nodered_heishamon_control.

omenukas avatar omenukas commented on June 26, 2024

It has been noticed that when the pump is set to run in curve mode and Softstart is enabled then it works correctly and the correction changes work. (in Beta version)

from nodered_heishamon_control.

edterbak avatar edterbak commented on June 26, 2024

Hi,

Can you confirm that this is with:
TOP76 = 0 (Heating_Mode)
TOP111 = 0 (Z1_Sensor_Settings)

IF it is different, i would like to know.

from nodered_heishamon_control.

geduxas avatar geduxas commented on June 26, 2024

Hi @edterbak i think i am in same problem right now. RTC not working as expected. Tried to play around, and RTC reports +4 in shift but set command didn't went to heishamon.

here is breaf output from log

image

from log it's clearly declares new shift to +4, but there is no command in log that actual do it.. (should i see it?) after that i have made some changes for DHW and log was filled with change commands immediately.

from nodered_heishamon_control.

edterbak avatar edterbak commented on June 26, 2024

The last update (flows 23.10 beta31.json) is a major one.
Can you test if the issue you are seeing is still present?

PS.
The grey-out of WAR is not an easy option I am afraid. This element does not easily allow change of text colors. I need to write it in a class for that, which takes some work.
First I want to get stuff working propperly befor I do the window dressing :)

from nodered_heishamon_control.

omenukas avatar omenukas commented on June 26, 2024

In the beta version, I don't understand how to connect the custom room temperature sensor.
System ->Sensors is empty, there is no selection and nothing can be recorded.
I tried to pin to Room temperature link-in, but then all Node Red broke and I did a restore to version 23.09.

from nodered_heishamon_control.

edterbak avatar edterbak commented on June 26, 2024

Yes.
In the flow (not dashboard) go to page [WP Input]
there you need to connect the incoming data nodes to.

it should be clear which one belongs where.

If you have done that. then in the dashboard (settings > sensors) you need to wait until all values have been populated in the dropdown menus. This can take a while.
After that you can select in the drop down which value you need. This one will be used from then on.

from nodered_heishamon_control.

edterbak avatar edterbak commented on June 26, 2024

this is why it is a beta.
no propper documentation yet .. sorry for that.

from nodered_heishamon_control.

omenukas avatar omenukas commented on June 26, 2024

I tried curve mode. T shift works correctly - it also changes in the pump.
However, I ran into another problem:
I have a script that finds the lowest temperature of all 4 rooms and gives it to the pump as the room temperature.
Temperatures.json

In this Beta version, as I understand it, in SYSTEM->Sensors I have to select a single room temperature sensor, which value will not necessarily always be the lowest. Is there any way to resolve this issue?

from nodered_heishamon_control.

edterbak avatar edterbak commented on June 26, 2024

In the tab WP Input, you can feed any signal to the Temperature link-in node.
If you have the script to calculate the measured value, you can feed that to the link-in node.
The flow does not need to know the different source of temperature. just a temperature. :)

Aditionally, in that tab you can also link in the room target temperature for RTC function.

from nodered_heishamon_control.

edterbak avatar edterbak commented on June 26, 2024

@omenukas sorry for taking this topic, also i am new to node-red, but your script should work fine, your script just get's all temp, and passes only lowest value.. so input should receive single lowest value. One thing that i am missing i'ts payload topic. Don't know if flow is looking for topic, but i use almost same for myself.. and after that just compile one payload with my custom topic name, and everything works fine.

Yes, the default is that 1 topic contains one value. Or multiple key/value pairs.
The drop down selected 1 topic Indeed. So you are right with your solution. Combine to calculate 1 value and set the topic manually.

from nodered_heishamon_control.

omenukas avatar omenukas commented on June 26, 2024

@edterbak Can we close this issue?

from nodered_heishamon_control.

edterbak avatar edterbak commented on June 26, 2024

Sure.
If your issue is solved. You can do the honour. 👍

from nodered_heishamon_control.

Related Issues (20)

Recommend Projects

  • React photo React

    A declarative, efficient, and flexible JavaScript library for building user interfaces.

  • Vue.js photo Vue.js

    🖖 Vue.js is a progressive, incrementally-adoptable JavaScript framework for building UI on the web.

  • Typescript photo Typescript

    TypeScript is a superset of JavaScript that compiles to clean JavaScript output.

  • TensorFlow photo TensorFlow

    An Open Source Machine Learning Framework for Everyone

  • Django photo Django

    The Web framework for perfectionists with deadlines.

  • D3 photo D3

    Bring data to life with SVG, Canvas and HTML. 📊📈🎉

Recommend Topics

  • javascript

    JavaScript (JS) is a lightweight interpreted programming language with first-class functions.

  • web

    Some thing interesting about web. New door for the world.

  • server

    A server is a program made to process requests and deliver data to clients.

  • Machine learning

    Machine learning is a way of modeling and interpreting data that allows a piece of software to respond intelligently.

  • Game

    Some thing interesting about game, make everyone happy.

Recommend Org

  • Facebook photo Facebook

    We are working to build community through open source technology. NB: members must have two-factor auth.

  • Microsoft photo Microsoft

    Open source projects and samples from Microsoft.

  • Google photo Google

    Google ❤️ Open Source for everyone.

  • D3 photo D3

    Data-Driven Documents codes.