The day energy entity was changed a couple of releases ago to bring it in line with all the other energy entities (to support long term statistics). Looks like that has inadvertently caused this issue. If you add this to the components config yaml, does it resolve this for you?

units: kWh

from sensor.fronius.

Sloneczna17 avatar Sloneczna17 commented on August 21, 2024

No, if I change in config yaml it only change tke name MWh to kWh but value is in MWh. For example my doday's prodeced energy was 35 kWh but I only see 0,03 kWh (or MWh depends what I use).
If I change the the unit of energy in castomize.yaml I said that the configuration.yaml join incorectly castomize yaml. I attached my configuration yaml and castomize yaml and entities after I change the unit in castomize.
Sorry for polish language.
castomize yaml
configuration yaml
fronis day energy1

from sensor.fronius.

colwilliamsnz avatar colwilliamsnz commented on August 21, 2024

I reverted the change made in my branch and I'm seeing no difference (see screen shot which is identical value BEFORE and AFTER). The only difference being there are no "long term stats" attributes in the reverted version which is why I changed it in the first place).

Screen Shot 2021-09-07 at 9 08 20 AM

I'm not sure that using customise.yaml is the right way of going about fixing this. How about changing the units for the Fronius sensor by adding "units: kWh"? Here's mine for reference:

  • platform: fronius_inverter
    ip_address: 192.168.1.71
    powerflow: true
    units: kWh
    power_units: W
    smartmeter: true
    smartmeter_device_id: 0

from sensor.fronius.

Sloneczna17 avatar Sloneczna17 commented on August 21, 2024

You have smartmeter and I don't but this is not the point. I set in configutation yaml units: kWh and after this I have every entitis in kWh but I have to change manually units to kWh because its stayed in MWh.
Before the upgrade of HA and Hacs integraton I didn't have to set the units in configutation yaml and have entities:
Fronius power in W, day energy in kWh, year energy in MWh, total energy in MWh.
Now when I set units: kWh I have day, year and total energy in kWh. Why? I don't know it is because of HA upgrade to 2021.9 or Fronius HACS integration. I did whole updates the same day.

from sensor.fronius.

nilrog avatar nilrog commented on August 21, 2024

Yes, @Sloneczna17, you are correct in that this is a change of behavior in this integration. It was introduced when support for long term statistics was added to comply with the new energy feature in HA. That said, having the different energy sensors report their values in different units as it was done before is not logical or practical.

If there is a need to have the DAY_ENERGY in kWh and the other energy sensors in MWh then, imo, the user can set units to kWh and define new template sensors to convert those sensors to MWh.

@colwilliamsnz
The reason why this behavior was changed is because the convert_units field was changed from false to energy for DAY_ENERGY to support the long term sensors. And as you can see here also the default units for these sensors are not equal (there are historical reasons for that).

    'year_energy': ['inverter', True, 'YEAR_ENERGY', 'Year Energy', 'MWh', 'energy', 'mdi:solar-power'],
    'total_energy': ['inverter', True, 'TOTAL_ENERGY', 'Total Energy', 'MWh', 'energy', 'mdi:solar-power'],
    'day_energy': ['inverter', True, 'DAY_ENERGY', 'Day Energy', 'kWh', 'energy', 'mdi:solar-power'],

If you look further down in the code you can see here there is special handling for the DAY_ENERGY sensor and that is no longer happening. So now the DAY_ENERGY will always be converted to units. And I believe that the current behavior is better and less confusing. But it will affect a number of people who were running this integration without specifying units or specifying it as Wh.

            if self._convert_units == "energy":
                _LOGGER.debug("Converting energy ({}) to {}".format(state, self._units))
                if self._units == "MWh":
                    self._state = round(state / 1000000, 2)
                elif self._units == "kWh":
                    self._state = round(state / 1000, 2)
                else:
                    self._state = round(state, 2)
            elif self._convert_units == "power":
                _LOGGER.debug("Converting power ({}) to {}".format(state, self._units))
                if self._units == "MW":
                    self._state = round(state / 1000000, 2)
                elif self._units == "kW":
                    self._state = round(state / 1000, 2)
                else:
                    self._state = round(state, 2)
            elif self._json_key == "DAY_ENERGY":
                # day energy always gets converted to kWh
                _LOGGER.debug("Converting day energy to kWh ({})".format(state))
                self._state = round(state / 1000, 2)
            else:
                _LOGGER.debug("Rounding ({}) to two decimals".format(state))
                self._state = round(state, 2)

If we want to support the old behavior where DAY_ENERGY was treated special then that if-statement needs to go into the energy if-statement.

The way forward now is either:

  1. Update the README to state that all energy sensors now use the same, configurable, unit (breaking change, but more consistent)
  2. Update the code to restore the old behavior while maintaining the support for long term sensors (non breaking change, but confusing with different units).

For me it doesn't matter as I have always used units: 'kWh'. But from a maintenance perspective and the new energy feature in HA I say that option 1 is the preferred one.

from sensor.fronius.

Gollam avatar Gollam commented on August 21, 2024

For me, it is more confusing that instead of 9.984 kWh, I now see 0.1 MWh for half a day, the granularity has decreased a lot!

from sensor.fronius.

UdoK avatar UdoK commented on August 21, 2024

The Energy Configuration is even complaining about the Fronius Day Energy in MWh
Solar Production energy should be in kWh

from sensor.fronius.

Related Issues (20)

Recommend Projects

  • React photo React

    A declarative, efficient, and flexible JavaScript library for building user interfaces.

  • Vue.js photo Vue.js

    🖖 Vue.js is a progressive, incrementally-adoptable JavaScript framework for building UI on the web.

  • Typescript photo Typescript

    TypeScript is a superset of JavaScript that compiles to clean JavaScript output.

  • TensorFlow photo TensorFlow

    An Open Source Machine Learning Framework for Everyone

  • Django photo Django

    The Web framework for perfectionists with deadlines.

  • D3 photo D3

    Bring data to life with SVG, Canvas and HTML. 📊📈🎉

Recommend Topics

  • javascript

    JavaScript (JS) is a lightweight interpreted programming language with first-class functions.

  • web

    Some thing interesting about web. New door for the world.

  • server

    A server is a program made to process requests and deliver data to clients.

  • Machine learning

    Machine learning is a way of modeling and interpreting data that allows a piece of software to respond intelligently.

  • Game

    Some thing interesting about game, make everyone happy.

Recommend Org

  • Facebook photo Facebook

    We are working to build community through open source technology. NB: members must have two-factor auth.

  • Microsoft photo Microsoft

    Open source projects and samples from Microsoft.

  • Google photo Google

    Google ❤️ Open Source for everyone.

  • D3 photo D3

    Data-Driven Documents codes.