hugen79 avatar hugen79 commented on August 9, 2024

In order to obtain good results, you need to modify the reflection bridge, then modify the software, and finally use a 75 ohm load for calibration.

from nanovna-h.

goscickiw avatar goscickiw commented on August 9, 2024

Yes, I know this, I mentioned that previously. If calibrating the whole system to 75 ohms is causing an issue that I haven't noticed yet, maybe the software impedance value could only affect the SWR (1:1 at 75 ohms) and Smith chart (center at 75 ohms) while the calibration is still to 50 ohms?

Also, how exactly would the reflection bridge have to be changed to accept both 50 and 75 ohm calibration?

from nanovna-h.

Pmax65 avatar Pmax65 commented on August 9, 2024

Hi goscickiw,

Yes, I know this, I mentioned that previously. If calibrating the whole system to 75 ohms is causing an issue that I haven't noticed yet, maybe the software impedance value could only affect the SWR (1:1 at 75 ohms) and Smith chart (center at 75 ohms) while the calibration is still to 50 ohms?

No, it is not only that, in case you don't apply a 50/75ohm adapter on CH0 during the calibration and the measurements, you get a flatness in the measurements that for the impedance offset could be up to 3.5dB in the return loss measures.
Note that there is no need to rebuild the whole Weston bridge to get a right measurements, it suffice a 50/75ohms minimum loss pad between the CH0 port and the DUT.

The only side effect is that the adapter reduces a little the dynamic of the measurements, but for RL shouldn't be a tragedy at all.

Have a nice day.

Massimo - IK1IZA

from nanovna-h.

goscickiw avatar goscickiw commented on August 9, 2024

Even with 50 ohm calibration and a converter, the 75 ohms (in system) will be displayed as 50 ohms (what the VNA sees at the converter), and 1:1 SWR and the center of the Smith chart will still be 50+0j ohms. I would like to be able to set 75 ohms as Z_0, only visually for proper values on the graphs.

So the 5.7 dB loss on the converter's resistors won't be a big issue? Currently I have some TP-75 transformers which have low loss but they only work properly up to 200 MHz, and I heard their inductive nature can affect the measurement.

from nanovna-h.

Pmax65 avatar Pmax65 commented on August 9, 2024

Hi goscickiw,
yes, if you place a minimum loss pad you get right measurements at cost of the reduced dynamic of the port. This is because it is a pure resistive (non-reactive) device in the useful range of frequency for which it is designed, so the calibration can easily embed its behaviour.
In that case you need to change the SW for center the Smith chart at Z0=75ohm of course.
I never tried the Macom TP-75 transformers for this scope, but my guess is that its reactance along the frequency range could be not fully predicted and for that I suppose that the calibration shouldn't be effective in this case.
Please, take care that this last is just an opinion of mine, I never checked it out.

Massimo - IK1IZA

from nanovna-h.

Pmax65 avatar Pmax65 commented on August 9, 2024

By the way (this is just a provocation of course).
Hugen could design and sold cheap SMA male to BNC female minimum loss pads for the nanoVNA.

They are just one 43.3ohm resistor in series to BNC hot terminal and an 86.6ohm resistor in parallel to the SMA male connector ;-)

Edit:
Maybe it could be better a simple 25ohm in series between the hot terminals of the connectors.
In that case the impedance seen by the Weston bridge is 100 ohm but it can be embedded in the calibration and the connection line to the DUT remains matched to 75ohm avoiding the flatness and I guess that the dynamic of the measurements could be better than compared to the minimum loss pad indeed.

from nanovna-h.

Related Issues (20)

Recommend Projects

  • React photo React

    A declarative, efficient, and flexible JavaScript library for building user interfaces.

  • Vue.js photo Vue.js

    🖖 Vue.js is a progressive, incrementally-adoptable JavaScript framework for building UI on the web.

  • Typescript photo Typescript

    TypeScript is a superset of JavaScript that compiles to clean JavaScript output.

  • TensorFlow photo TensorFlow

    An Open Source Machine Learning Framework for Everyone

  • Django photo Django

    The Web framework for perfectionists with deadlines.

  • D3 photo D3

    Bring data to life with SVG, Canvas and HTML. 📊📈🎉

Recommend Topics

  • javascript

    JavaScript (JS) is a lightweight interpreted programming language with first-class functions.

  • web

    Some thing interesting about web. New door for the world.

  • server

    A server is a program made to process requests and deliver data to clients.

  • Machine learning

    Machine learning is a way of modeling and interpreting data that allows a piece of software to respond intelligently.

  • Game

    Some thing interesting about game, make everyone happy.

Recommend Org

  • Facebook photo Facebook

    We are working to build community through open source technology. NB: members must have two-factor auth.

  • Microsoft photo Microsoft

    Open source projects and samples from Microsoft.

  • Google photo Google

    Google ❤️ Open Source for everyone.

  • D3 photo D3

    Data-Driven Documents codes.