kromosomX avatar kromosomX commented on July 18, 2024 1

Yeah, i think the dafult cooling recovery feature of savecair works OK. But the free cooling feature of savecair does not (too many limitations). Airiana works much better for cooling.

from airiana.

BeamCtrl avatar BeamCtrl commented on July 18, 2024

Hello, nice to see you take an interest in this project. I would guess an update to use an TCP implementation would be quite straight forward by updating the request class to be confiugrable TCP or RTU, but I’m not sure why you would need to. Running this setup on a Rpi is more or less equvalent to an IAM but with added functionality. What Functionality are you looking for by going thru the IAM?
Best regards /Daniel

from airiana.

kromosomX avatar kromosomX commented on July 18, 2024

Hi, it's not the functionality. It's convenience. I already have the IAM module connected. I also have the RPI but it's used as an interface for the Vaillant heat pump. For the time being i'll just integrate the Systemair into Home Assistant via modbus2mqtt and use the MQTT Climate integration and set up some autiomations/scripts to tweak it via Home Assistant. I will 'borrow' some of your ideas. I am already controling some of the functionality (Kitchen Hood and Central Vacuum Modes) of the Systemair via digital inputs.

The Systemair automation is not working as i would expect by default. For example I have to set the temperature very low (like 12C) to stop the recuperation of heat in the summer (during the day, during the night it goes into FreeCooling mode).

Also if I use on demand automation in connection to humidity and the humidity is to high it increases the ventilation even if the outside air is hoter and more humid.

from airiana.

BeamCtrl avatar BeamCtrl commented on July 18, 2024

I did a fast implementation of pyModbusTCP to be used as request handler, I have not been able to test it since I have no IAM. give it a shot and tell me if it has alot of buggs ;).
//daniel,
note that you will need to edit the /etc/systemd/system/airiana.service file to add "TCP" as an cmd line arg. and restart the service. can be done with ."./restart" in the airiana directory after a systemctl "daemon-reload"
//Enjoy

from airiana.

kromosomX avatar kromosomX commented on July 18, 2024

Hi,
thank you for the TCP implemantation.
I made a few changes (commented out some modbus RTU related lines and fixed a few things in request) and now i can get airiana-core.py running directly. There are some read and write errors comming up and temperature values are off by one decimal but it is runnning.

I have a VTR300, so i presume that savecair should be set to True. Right?

I'll play a little more with it and report back the changes that I make.

Thanks again. I also have to figure out how to issue pull requests so the changes can be merged back after I clean them up a little.

from airiana.

BeamCtrl avatar BeamCtrl commented on July 18, 2024

it should automatically set to true if it gets a positive response on a SaveCair adress, the savecair uses a different address space compared to the legacy systemair units
The automatic update feature may cause you to loose your changes if you do not disable it or push your changes into the repo. I will also try to do a configuration file done so we do not have to push IP-address into the repo.
//D

from airiana.

kromosomX avatar kromosomX commented on July 18, 2024

I disabled the update for the time being as I am going on a short trip tomorrow and I won't be back before Thursday.

I managed to get everything up and running. Now the automatic SaveCair recognition is working (i moved setting the modbus client variable for TCP in the airiana-core.py also)

If i set the debug command line my pi freezes after a couple of minutes (at least when i run it from the command line/ didn't try it as a service).

If you do any changes in the meanwhile i will merge my changes with yours manually when i get back and then i'll try to figure out how to do pull requests.

I presume that i should keep the VTR300 in manual mode, correct? Are there any specific settings that i should set on the VTR or NOT set for airiana to work?

I have a ton of questions regarding the features of airiana (shower mode, preemptive cooling,...) but that will wait until I come back.

Thank you for your help. BTW What unit do you use?

from airiana.

BeamCtrl avatar BeamCtrl commented on July 18, 2024

Great fun to hear you are getting it working, to have it not go into conflict with the existing features what I have done on my VTR300/savecair is disable free cooling, humidity recovery.
If you toggle the auto on/off you will turn all automated features off, and the airiana unit will only read from the unit.

I will have to do a write up of how the features work and what is needed by the user to get it working, a sort of manual that is clear ;).

when strange stuff happens you can always check the err log in ./RAM/err for any hints on why debug causes crashes.

anyway great to have you onboard to get the TCP -> IAM working, its hard to test without one =).
best regards// Daniel.
have a great trip!

from airiana.

kromosomX avatar kromosomX commented on July 18, 2024

Hi,
you probably don't get temperatures over 30C in Västerås very often? Hehe.The hack for the exchanger works only only until 30C outside temperature. So I was scratching my head today (31C) as why the exchanger is not working. When the outside temperature fell below 30C everything started working as expected. If I enable Cold Recovery and set the temperature below outside temperature the exchanger works. Would using this technique interfere with other functionality? I'll rewrite the whole logic for starting and stoping the exchanger on Savacair units if it doesn't interfere with other functionality.

Best regards,

Tomaž

from airiana.

BeamCtrl avatar BeamCtrl commented on July 18, 2024

It is true not that often ;), how ever, the hack to turn on the exchanger is a legacy from my old VR400 unit, I’m actually considering removing the whole block and just relying on the internal heat recovery logic. Do you feel it works well?

My aim with it is to get as much revovery as possible when cooling is no longer possible.

from airiana.

BeamCtrl avatar BeamCtrl commented on July 18, 2024

I’ve been running my savecair unit without the exchange hack for cooling recovery and it seems the unit handles it quite well. I will remove the force exchanger section shortly.

from airiana.

BeamCtrl avatar BeamCtrl commented on July 18, 2024

implemented additions in PR 5.

from airiana.

Related Issues (15)

Recommend Projects

  • React photo React

    A declarative, efficient, and flexible JavaScript library for building user interfaces.

  • Vue.js photo Vue.js

    🖖 Vue.js is a progressive, incrementally-adoptable JavaScript framework for building UI on the web.

  • Typescript photo Typescript

    TypeScript is a superset of JavaScript that compiles to clean JavaScript output.

  • TensorFlow photo TensorFlow

    An Open Source Machine Learning Framework for Everyone

  • Django photo Django

    The Web framework for perfectionists with deadlines.

  • D3 photo D3

    Bring data to life with SVG, Canvas and HTML. 📊📈🎉

Recommend Topics

  • javascript

    JavaScript (JS) is a lightweight interpreted programming language with first-class functions.

  • web

    Some thing interesting about web. New door for the world.

  • server

    A server is a program made to process requests and deliver data to clients.

  • Machine learning

    Machine learning is a way of modeling and interpreting data that allows a piece of software to respond intelligently.

  • Game

    Some thing interesting about game, make everyone happy.

Recommend Org

  • Facebook photo Facebook

    We are working to build community through open source technology. NB: members must have two-factor auth.

  • Microsoft photo Microsoft

    Open source projects and samples from Microsoft.

  • Google photo Google

    Google ❤️ Open Source for everyone.

  • D3 photo D3

    Data-Driven Documents codes.